Home Page
Company Profile
Our Products
Warmers
Open Care System
Incubators
Phototherapy Units
Baby Bassinet
Patient Warming System
Foetal Doppler
Syringe Pump
Infusion Pump
Pulse Oximeter
Infantometer
Ambu Bag
O2 Hood
Laryngoscope
Baby Weighing Scale
O2 Anlayser
Humidifier
Operation Theatre Lights
MEDICAID
 
Home » Products » Infusion Pump » Infusion Pump

Infusion Pump



Infusion Pump

Product Code : 08

Product Specification

Infusion Pump

Application:

Continuous low flow rate infusion of fluid drug and transfusion in ICU or CCU, Continuous infusion of anesthetic, anti-cancer agent and nutrient to immature infant or newborn.s

The handy drop pump

Small Size, low weight and high-technology, incorporated into a compact design. Quick and simple mounting at the bedside, via universal clamp.

Three different modes for Infusion

  • Simple Drop Rate Mode.
  • Volume Target Mode.
  • Time Target Mode. Customizable setup as per user's choice: 4-factory preset and 4 customized IV sets library along with facility to set default infusion set.. 5 levels for Alarm sound tone.
  • 5 levels for K.V.O. flow rate.
  • 5 levels for Keypad tone.
  • ml/hr or Drops/min unit selection for Volume Target and Time Target mode' Facility to set default infusion mode for simplicity.

Self-testing Function

After power is turned on, the microprocessor in the TIASHI-DP automatically executes a self-diagnostic in order to ensure that all functions are working properly That also monitors every corner during infusion

Easy identification of alarm condition

Obvious and recognizable attention lights Flashing Back-light of LCD display for Audible and Visible alarm function.

Free Flow Protection

Tubing clamp (Stopper) mechanism automatically closes the IV tubing to prevent unrestricted flow of solution to the patient when the door is opened.

Keep-Vein-Open Function

When Infusion is completed, the pump automatically engages the K.V.O. function to maintain a minimum flow rate of 1 ml/h or 1 drops/min. This prevent the Infusion line from blocking due to blood clots. Communication Port: RS - 232C connector for external communication and to upgrade.

Easy Battery Replacement

The battery pack can easily be replaced simply by opening the battery cover at the back of the unit.

External DC power Compatible:

  • Connects to external DC power source, enabling use of the pump within an ambulance.
  • Air bubble detector (Optional).
  • Air bubble detector can detect bubble size between SO to 1S0 micro litre (User settable). Alarm available for air bubble volume accumulated overtime (1 ml over 0.5h).

Improved Drop Sensor

The drop sensor controls flow rate of IV fluid, and detect irregularities in drop count. Digital signal processing for better perfomance.

Technical Specifications

Infusion

Overall Accuracy +/- 1 %
Setting Modes Flow rate only, flow rate + volume target, time + volume target
Flow rate ranges 0 -300 drops/min or 0 -300 ml/hr.
Infusion volume limits 0 -60000 drops or 0 -10000 ml
Time range 0 -99:00 hrs
KVO rate 1 to 5 % of selected infusion rate but min. 1 drop/ min or 1 ml/hr

Mechanical

Pumping Mechanism Linear Peristaltic
Drop Sensor External
Air Bubble Detector** Ultrasonic Adjustable 20- 150µ1 15, 20, 40, 60 drops/cc.
Set type Facility to add four customized sets as per user's choice.

Indicators

Alarms: Run & Mains. No mains, Very low battery, Low battery, Sensor error, Low flow, High flow, Door open, Near End, End of infusion, KVO, Air in line, System error.

Special Features

Free Flow Protection A unique lever mechanism protects from free flow in case of accidental door opening.
Digital Processing of Drop Sensor Signal Digital processing of drop sensor signals allows you to the change the infusion parameters without the need for infusion interruption.
Adjustable air in line alarm threshold
The size of air bubble to be detected can be set in the range of 20 to 150µ1
Flow Rate & Volume Unit selection Option to select Flow Rate Unit in terms of drop/mill or ml/hr & Volume Unit in terms of drops or m1.

Power

External power supply AC Input range170 -270 VAC, Frequency 50 -60 Hz
12 Volts, l Amp DC output Supply
Power Consumption 12 Watts max.
Build in battery 8.4 V, 2.1 AHr Ni -MH battery for increased durability.
Continuous operation for about 4.5 hrs. at an operating rate of 20 drops/mill or 20 ml/hr with assign I. V. Set under standard conditions.
Classification Class II, IPX1 (Drip Proof)
Operating Conditions Ambient Temperature 05 to 40o C Relative Humidity 20 to 90 % (no condensation) Atmospheric 70 to 106 kPa pressure
Housing & construction

Compact and Robust A.B.S Plastic

Weight Approx. 2.4 Kgs.
Dimensions Approx. 250 (L), 245 (H), 90 (W)
Mounting On a pole or bed-fra

Medicaid having a policy of continuous product improvement reserves the right to alter specification/physical design without prior notice .
<< Back


 

Warmer
Warmer
Medical Radiant Warmers
Medical Radiant Warmers
Medicaid Warmer
Medicaid Warmer
Resuscitation Unit
Resuscitation Unit
Neonatal Open Care Systems
Neonatal Open Care Systems
Incubator
Incubator
Phototherapy Unit
Phototherapy Unit
Undersurface Phototherapy Unit
Undersurface Phototherapy Unit
Baby Bassinet
Baby Bassinet
Patient Warming System
Patient Warming System
Doppler
Doppler
Syringe Pump
Syringe Pump
Infusion Pump
Infusion Pump
Pulse Oximeter
Pulse Oximeter
Infantometer Big
Infantometer Big
Ambu Bag
Ambu Bag
Oxygen Hood
Oxygen Hood
Laryngoscope
Laryngoscope
Baby Weighing Scale
Baby Weighing Scale
O2 Analyser
O2 Analyser
Humidifier
Humidifier
Operation Theatre Light
Operation Theatre Light
Operation Theatre Lights
Operation Theatre Lights
Operation Theatre Lights (MOT)
Operation Theatre Lights (MOT)
 


Related products/services from other companies

» MEDICAL ENTERPRISES
Horizontal Laminar Air Flow Systems
Shirt
Horizontal Laminar Air Flow Systems
Writing Magnetic Board
Shirt
Writing Magnetic Board
X-ray Viewing Screen (LED)
Shirt
X-ray Viewing Screen (LED)

» HOSPILINE EQUIPMENTS PVT. LTD.
SPHINCTEROTOME/PAPILOTOME
Shirt
SPHINCTEROTOME/PAPILOTOME
HEATING / COAGULATION PROB (UNI-POLAR)
Shirt
HEATING / COAGULATION PROB (UNI-POLAR)
Kobara Kx Cam II-Z
Shirt
Kobara Kx Cam II-Z

» SAXENA SCIENTIFIC INSTRUMENT
Incubator Bod Tester
Shirt
Incubator Bod Tester
Medical Equipment
Shirt
Medical Equipment
» Trade Offers
Blood Analyzer Blood Analyzer
Posted on: 17 May 2012 [China]
Blood Analyzer Advanced percentage analysis principles Large memory for 10000 results ... more

B Mode Ultrasound Scanner Kx2000e B Mode Ultrasound Scanner Kx2000e
Posted on: 15 May 2012 [China]
Exquisite trolley design, contracted hardware design, pursuing the best cost performance. ... more

Quadriceps Exercise Chair (Children) Quadriceps Exercise Chair (Children)
Posted on: 15 May 2012 [India]
Quadriceps exercise chair (children): hardwood constructed chair with cushioned seat and b... more

Sanding Unit Overhead Sanding Unit Overhead
Posted on: 15 May 2012 [India]
Sanding unit overhead: heavy & wide based stand adjustable in height, is fitted with 6" wi... more

Prone Crawling Board Prone Crawling Board
Posted on: 15 May 2012 [India]
Prone crawling board: unit helps the child learn body control, shifting weight, changing d... more

Supinator & Pronator (Zig-Zag Type) Supinator & Pronator (Zig-Zag Type)
Posted on: 15 May 2012 [India]
Supinator & Pronator (Zig-Zag Type): Bright laminated six wooden discs & six metal rings s... more
 
Copyright © 2011-12 by MEDICAID All Rights Reserved.