Neonatal Open Care Systems Medicaid resuscitation unit IRW 80 is technologically advanced (micro processor controlled) mobile unit with baby bassinet, oxygen and suction facility.
Control panel:
Available with a choice of thermal control system
- Skin / air / manual control
- Advance micro processor controlled with self check on the status of the electronic circuitery.
- Digital display of skin/ air temp., set temp.
In addition, the Skin / Air temp. display is larger than the other set temp. display
Skin/Air temp. pulsates in the event of temp. deviation more than +0.5oC.
A "%Power" indicator on this panel provides a bar chart display, to show the level of power provided to the radiant heating elements as an indication of the heating output of the system.
The control panel is also the heart of a completely integrated alarm system with both audible and visual indicators in the event of :-
- Temp. Deviation of 0.5oC above or below the set temp.
- Probe failure, automatically cuts off the heater in case of probe failure.
- Power supply interruption.
Programmable features:
- Set temp. - high limit & low limit
- Mute time
- Manual time
- Apgar timer
- Includes ventury / slow suction and oxygen facilities.
- Digital time display of apgar scoring procedures
A number of accessories such as monitoring shelf, o2 flow meter, iv rod etc.. incorporated into the panel of the Medicaid infant resuscitation unit.
BED UNIT
- The spacious bassinet incorporates easily removable bassinet sides, which fold down for maximum access to the infants these individually look in place, for added security. With Tendelburg/Fowler positioning of the bed.
- The Integration of the quartz halogen lamp means that an accurate assessment of the infant colour and behaviour may be made at all times.
- Heater assembly
- The heater assembly located above the centre of the support structure consists of a radiant heater, reflector, integral examination light.
- The reflector focuses the radiant heat energy from the heater module directly on the bed surface to minimize energy loss and provide even heating of the patient.
- The intuitive operation of the system gives the care giver, the freedom to concentrate on the infant, rather than the equipment.
- On the whole doctor will discover that this system has addressed all his concerns and much more about neonatal open care.
- The integration of the quartz halogen lamp / LED examination light means that an accurate assessment of the infant colour and behaviour may be made at all times
Technical specification
- Height: 1865mm
- Length: 1020m
- Width: 560mm
- Infant tray: 670x535mm
Electrical
- Power supply: 200v.50htz.
- Heater power: 500 watts.
Halogen Examination Lamp (12 Volts, 50 Watts)
To provide accurate assessment of Infant colour and sufficient illumination during procedures Medicaid having a policy of continuous product improvement reserves the right to alter specification/physical design without prior notice .
|